<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-12 09-29-43
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 44 dBuV YLEX
Pilot RDS Phase Difference
7.6 kHz 2.8 kHz 56 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 64 kHz 19200 0,1094
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,2 dBr 1,71 dBr 4,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 9:29, 12.12.2025
RT
"YleX "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 13 kHz % above 76 kHz: 0,1094 Acquired: 2025/12/12 9.28.38 Total samples: 19200 Equivalent time: 0:16:00 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,9 dBr MIN: -0,2 dBr AVE: 1,71 dBr % above 12,2 dBr: 0,0 Last value: 1,0 dBr (2025/12/12 9.28.38) 09.14 09.16 09.18 09.20 09.22 09.24 09.26 09.28 0 2 4 Pm [dBr]